If a material blocks electricity, it probably blocks heat too. It sounds reasonable. It is wrong often enough to matter.
Diamond is a wide-band-gap electrical insulator, and it conducts heat better than copper. Graphite felt conducts electricity and is used as high-temperature thermal insulation. Neither is an exotic edge case — together they are a clean demonstration that the two properties are separate.
That separation is not academic. In electrical equipment it is the whole design problem, because you almost always want one and not the other.
Table of Contents
What each one actually does
| Property | Electrical insulation | Thermal insulation |
|---|---|---|
| What it limits | Unwanted electric current and leakage | Heat transfer |
| Driving force | Voltage difference | Temperature difference |
| Carried in the material by | Mobile charge carriers | Lattice vibrations, plus free electrons where present |
| Main property | Electrical resistivity | Thermal conductivity |
| Typical unit | Ω·m | W/(m·K) |
| Characteristic property | Dielectric strength, in kV/mm | Thermal conductivity, in W/(m·K) |
| Key design parameter | Clearance, creepage, insulation thickness | Thermal resistance, often as R-value in m²·K/W |
| Typical failure mechanism | Breakdown, tracking, flashover | Degradation, melting, burning, or excessive heat transfer |
The failure row deserves attention. Electrical insulation has a threshold. Push past it and you get a puncture or a flashover, rapidly and usually permanently in solids. Thermal insulation generally has no breakdown threshold analogous to dielectric breakdown — its heat-transfer performance changes continuously as conditions change, although the material itself can eventually degrade, shrink, melt or burn once its temperature limits are exceeded.
That difference shapes how each one is specified and tested.
Why the two often travel together in metals
In a metal, free electrons carry both charge and heat. That is why copper is excellent at both and why, as a rough guide, good electrical conductors also conduct heat well. The relationship between electrical and thermal conductivity in metals is described by the Wiedemann–Franz law, which holds reasonably for many metals over a moderate temperature range.
So the connection is real — on the conductor side.
Why it breaks down on the insulator side
In non-metals there are few free electrons, so heat travels mainly by lattice vibrations. Those vibrations do not need mobile charge. A material can therefore be an excellent electrical insulator and still pass heat efficiently, provided its structure carries vibrations well — which generally means a stiff, ordered, low-defect crystal.
Typical order-of-magnitude values follow. Actual values depend strongly on grade, structure, density, processing and temperature.
| Material | Thermal conductivity, approx. W/(m·K) | Electrically |
|---|---|---|
| Copper | Several hundred | Conductor |
| Diamond | Higher than copper | Insulator |
| Aluminium nitride | Order of 100 or more | Insulator |
| Alumina (Al₂O₃) | Tens | Insulator |
| Unfilled epoxy | Well under 1 | Insulator |
| PVC, XLPE | Well under 1 | Insulator |
| Still air | Around 0.026 at room temperature and atmospheric pressure | Insulator |
| Mineral wool, foams | Around 0.03 to 0.05 | Insulator |
Look at the bottom half of that table. The materials used as building thermal insulation are not good at blocking heat because of any electrical property. They work by trapping still air in small pockets, so convection is suppressed and the low conductivity of air does the work. Their electrical behaviour is incidental.
The conflict inside electrical equipment
Here is the part that matters on the job.
An energised conductor generates heat mainly through its electrical losses, such as I²R losses. In AC insulation systems, dielectric losses can also contribute. That heat has to get out, and the insulation is often part of the thermal path from the conductor to the surrounding environment.
So the insulation sits in a genuine contradiction:
- It must limit current as completely as possible.
- It should impede heat as little as possible.
Many common polymeric cable and winding insulation materials have thermal conductivity well under 1 W/(m·K), so they can act as a thermal blanket around the conductor they are protecting. This is not a design oversight — it is a trade-off that has to be managed.
You can see how it gets managed across different equipment:
Cables. Current-rating calculations treat the insulation, bedding, sheath, and the surrounding soil or air as a chain of thermal resistances. The thermal resistivity of the insulation is one of the parameters used in the current-rating calculation, alongside the thermal resistance of the surroundings — the approach set out in IEC 60287-1-1 and IEC 60287-2-1. The same cable buried in dry sand and in wet clay carries different current, for purely thermal reasons.
Motors and generators. The winding insulation system separates turns electrically while forming part of the heat path out of the copper. Slot fill quality, impregnation, and void content all affect thermal performance as well as dielectric performance. A poorly impregnated winding runs hotter and ages faster.
Transformers. Oil does two jobs at once. It is the dielectric and the coolant. Paper insulation on the windings limits current but also adds thermal resistance between the winding and the oil, which is why insulation thickness affects the thermal path as well as the electrical insulation system.
Power electronics. This is where the conflict is sharpest. A device dissipating tens or hundreds of watts must be electrically isolated from the heatsink. The answer is materials chosen to break the usual polymer trade-off — ceramic-filled silicone pads, alumina or aluminium nitride substrates, mica sheets, ceramic-filled potting compounds. All of them are attempts to get useful dielectric strength and useful thermal conductivity in the same layer.
The term that causes the most confusion
Thermal class is not thermal insulation.
When a motor is described as Class F, that refers to the thermal class assigned to the electrical insulation system based on its thermal endurance, under IEC 60085. It says nothing about the material’s ability to insulate against heat.
Class H therefore indicates a higher thermal class than Class F. It does not mean the insulation blocks more heat. Read the class as heat endurance of the electrical insulation, not heat blocking by the insulation. The two ideas share a word and nothing else.
They are tested completely differently
There is no overlap in method, which is a useful clue that they are separate properties.
Electrical insulation is assessed by insulation resistance, polarization index, withstand voltage, partial discharge, dissipation factor and tracking resistance. These tests evaluate how the insulation behaves under electrical stress, leakage, discharge, ageing or surface-tracking conditions.
Thermal insulation is assessed by thermal conductivity and thermal resistance measurements — guarded hot plate and heat flow meter methods — plus temperature rise testing on assembled equipment. These apply a temperature difference and measure heat flow.
A megohmmeter result does not tell you about thermal performance. A thermal conductivity measurement does not tell you about dielectric strength. If someone claims a single figure covers both, they are quoting one and guessing the other.
Quick decision guide
| If you need to… | You want… |
|---|---|
| Stop current between a conductor and earth | Electrical insulation, rated for the voltage |
| Keep heat inside a pipe, tank or building | Thermal insulation, specified by thermal conductivity |
| Isolate a semiconductor from its heatsink | Both — an electrically insulating, thermally conductive interface |
| Increase a cable’s current-carrying capacity | Improve heat removal and reduce losses, while staying within the insulation temperature limit |
| Protect insulation from an external heat source | A thermal barrier, plus an appropriate thermal class |
That fourth row catches people out. When a cable runs hot, the instinct is to look at the insulation. Often the answer is in the installation — grouping, depth, soil conditions, ambient temperature, ventilation. The insulation is doing its job; the heat has nowhere to go.
FAQ
Is every electrical insulator also a thermal insulator?
No. Ceramics such as alumina and aluminium nitride are electrical insulators with useful thermal conductivity, and that combination is exactly why they are used in power electronics. The overlap exists in many common polymers, but it is a property of those materials, not a rule.
Is every thermal insulator also an electrical insulator?
Usually, but not always. Graphite felt is used as high-temperature thermal insulation and conducts electricity. Never assume a material is safe to contact electrically because it was sold as thermal insulation.
Can building insulation be used to insulate a live conductor?
No. Materials like mineral wool and foam boards are specified by thermal conductivity and fire performance, not by dielectric strength or voltage designation. They have no place in an electrical enclosure as a dielectric.
Why does insulation thickness affect cable current rating?
Because heat generated in the conductor passes through the insulation on its way out. Thicker insulation adds thermal resistance to that path, so the conductor runs hotter for the same current. Thickness helps electrically and hurts thermally, which is one reason cable design is a balance rather than a maximisation.
Does moisture affect both types?
Yes, in different ways. In porous thermal insulation, water can replace air in the pores and substantially increase heat transfer. In electrical insulation, moisture can increase leakage current and, depending on the material and its condition, reduce dielectric strength.
What material gives good performance in both roles?
Thermally insulating and electrically insulating at once usually means a low-density polymer or foam. Electrically insulating and thermally conducting means ceramics and ceramic-filled compounds. Which you want depends entirely on whether the heat is something you are keeping in or getting out.